Temp. Range : 5 º C to 60 º C Accuracy : ± 0.1ºC to ±
0.5ºC
Applications
These equipments are primarily designed to meet the requirements of
Biochemical Oxygen Demand tests, it can also be used in applications
like incubation serum studies, study of enzymatic digestion processes,
tissue culture, preservation of vacancies, long term sample storage,
fruit fly, immunological works etc.
 |
Construction
Triple walled, exterior of CRCA/GI non-contaminant epoxy powder coated
& interior of AISI S.S. 304 with PUF / Glasswool insulation. An inner
full view acrylic door & outer double walled metal door with PUF/ Glass
wool insulation magnetic catch & lock
Circulation
Forced air circulation to ensure uniform temp
Heaters
S.S. 'U' type tubular nichrome wire heater with S.S. sheathing
Refrigeration System
CFC Free hermetically sealed compressor provides temperatures for below
ambient condition Temp. Control
A solid state Digital controller housing all the controls with PT-100
sensors. Interior Illumination
Flourescent lights are provided for viewing with door limit switch. |
Optional
For increased utility in Bacteriology, Biology, Virology, Oceanography,
Water Pollution, Sewage, Agriculture, Food research, Physiology,
Immunology, Radiobiology & Allied Laboratories, this incubator can be
provided with following features at extra cost. Flourescent interior
illumination with Cyclic system, shaking platform for flasks & glassware
with speed controller, Temp & Humidity system, carbon dioxide + air
mixture injection inlet.. GMP models / Complete S. S unit,
Microprocessor based PID temp. Controller with printer interface (Centronic
Port) PC interface with RS 232 CPC / RS-485 for multiple networking of
controller. Profile controller for Ramp / Soak for cyclic applications
etc.
Validation Protocols
DQ, IQ, OQ & PQ Protocols with complete documentation & certification
traceable to national & International standards
Safety Features
Built-in temp. deviation audio visual alarm. Safety thermostat for over
shoot temp. cut off safety circuit to cut off the whole system in case
of malfunction (Only applicable in microprocessor based models) HRC
fuses for compressor heaters & mains, time delay circuit for safety of
compressor etc. Special Care
A suitable K. V. A. Servo Controlled Voltage Stabilizer is strongly
recommended Technical Specification
| Model BCI -13 |
Size In Cu. Ft |
Internal Dimension in CMS |
Capacity In ltrs. |
No. of shelves |
| BCI-A |
3 |
40 X 40 X 57 |
90 |
2 |
| BCI-B |
6 |
50 X 50 X 70 |
175 |
2 |
| BCI-C |
10 |
57 X 57 X 88 |
285 |
3 |
| BCI-D |
12 |
60 X 60 X 95 |
340 |
3 |
| BCI-E |
16 |
70 X 70 X 95 |
450 |
4 |
* Due to continuous development &
improvements in design, we reserve the right to change the specification
without notice

|