 Environmental Controller / Dehumidifier (Vertical / Horizontal)

Humidity Range :35 % RH Accuracy : +/3 % RH

These equipments are capable of maintaining Relative Humidity 35% RH to 45% RH & are mainly used in Pharmaceutical Laboratories Capsules, Strip packing, Tablet Section, Packing Rooms, Processing Industries, Printing & Lithography, Photographic Industries, Communication equipment rooms, Computer & data storage various other purposes

Dehumidifier, Dehumidifier Environmental Controller, Dehumidifier Vertical Environmental Controller

Construction
Heavy gauge construction of CRCA sheet or AISI Stainless steel, Robust angular structure removable casing panel makes all parts easily accessible for adjustments & service when required

Working of Environment Controller (De-humidifier)
The equipment is based on refrigeration principle. It removes the moisture content of humid air in an enclosed room & condenses the moisture of the humid air into water which continuously drops into tray. No chemicals or dehydrating substances are used Relative humidity can be maintained depending upon  the cubic feet volume, the temp & no. of occupants in the room. The walls & ceilings should be vapour proof to minimize infiltration of moisture into the room

Refrigeration system
It is fitted with a hermetically sealed compressors to operate on 230 volts , Single phase 50Hz, with heat exchanging coil, water condensing coil & fan motor assembly. The unit is mounted on a trolley with a water collection tank at the bottom.

Dimensions
Horizontal Model overall Size : 30”H x 18”W x 18”D
Vertical Model overall Size : 42”H x 22”W x 24”D

Application
The following are the required conditions for installation of Environmental controller (Dehumidifier)

1.0 Tonne 2500 cu. ft. 5
1.5 Tonnes 3750 cu. ft. 7
2.0 Tonnes 5000 cu. ft. 9

Room Temperature
When operating the equipment the room temp. will tend to rise on account of its moisture removal latent heat load & the electrical motor operating in the equipment, A sufficient capacity Air Conditioner given below has to be installed along with the Environmental Controller (De-Humidifier) The total heat load thus added to the room is given under.

1 Tonne 2500 BTU 1 Tonne
1.5 Tonnes 9000 BTU 1.5 Tonnes
2 Tonnes 12000 BTU 2 Tonnes

RH Conditions :
A few of the typical temperature & the corresponding Relative Humidity conditions attainable in a room are given here under

70 ˚C F or higher 45 %
74 ˚C F or higher 40 %
81 ˚C F or higher 45 %

* Due to continuous development & improvements in design, we reserve the right to change the specification without notice

Products

Autoclave
B. O. D Incubator
Constant Temperature Circulating Bath
Deep Freezer
• Dehumidifier
Humidity Chamber
Ice Flakers
Laboratory Oven
Laminar Flow
Low Temperature Circulating Bath

Muffle Furnace
Stability Chamber
Tergo Tometer
Thermal Shock Chamber
Tray Dryer
Ultra Low Temperature Freezer
Universal Water Bath
Vacuum Oven
Viscometric Bath
Water Still

Cold Chamber
Low Temp. (Horizontal / Frost Free Vertical)
Walk - In Incubator / Cooler
Walk - In Stability Chamber
Walk - In Humidity Environmental Test Chamber
Salt Spray Corrosion Cabinet
 

Designed & Hosted by : MID   Promoted by : GID