Humidity Test Chamber / Environmental Test Chamber

Temp Range : 10°C above ambient to 60°C /10 °C to 60 °C /
-10°C to 60°C, Accuracy : ± 0.2 °C
Humidity Range : 40% to 98 % RH Accuracy :  ±  3 % R.H

Application :
These equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, tests on packages, paints & varnishes, cement plants, apparatus & materials for simulated tropical & extreme tropical conditions & for botanical & zoological investigations, testing of chemicals, drugs, pharmaceutical, cosmetics, medicine, capsules etc.


Construction :
Double walled, the exterior is made of CRCA with non-contaminant epoxy powder coated & interior is made of AISI S.S 304 with PUF/Glasswool insulation, double walled door with PUF/Glasswool insulation.
 

Air Circulation :
Forced air circulation to ensure uniform temp.

Heating & Humidification :
Air heaters are provided for heating above ambient temperatures. A water boiler with reservoir & float valve produces steam for humidifying the chamber.

Refrigeration System :
A hermetically seated compressor with CFC Free refrigerant provides temperatures below ambient conditions.

Temp. Control :
A Solid State Temp. control with panels housing all the controls & PT-100 Sensors are used as wet & dry bulbs.

Optional :
Model Available as per GMP / complete S. S unit & direct Temp.& RH°. readout, strip chart recorder, Microprocessor based
PID temp. Control with printer interface (Centronic Port). PC interface with RS232CPC / RS-485 interface for multiple networking of controller. µP Profile Controller for Ramp / soak for cyclic applications chamber illumination with fluorescent or U. V lamps.

Humidity Test Chamber, Environmental Test Chamber

Validation :
DQ, IQ, OQ & PQ  Protocols with complete documentation & certification traceable to National & International Standards.

Safety Features :
Built-in temp. deviation, audio/ visual alarms.
Safety thermostat for over shooting of temp. Safety circuit to cut off the whole systems in case of malfunction. (Only applicable to Microprocessor based models). HRC fuses for compressor heaters & mains.

Special Care :
Suitable K.V.A. Servo Controlled Voltage Stabilizer is strongly recommended.

Technical Specification

HC-A 45 X 45 X 45 1.5 K.W.
HC-B 45 X 45 X 71 1.5 K.W.
HC-C 70 X 70 X 55 2.5 K.W.
HC-D 100 X 100 X 100 3.0 K.W.
HC-E 230 X 110 X 110 4.0 K.W.

* Due to continuous development & improvements in design, we reserve the right to change the specification without notice

Products

Autoclave
B. O. D Incubator
Constant Temperature Circulating Bath
Deep Freezer
Dehumidifier
Humidity Chamber
Ice Flakers
Laboratory Oven
Laminar Flow
Low Temperature Circulating Bath

Muffle Furnace
Stability Chamber
Tergo Tometer
Thermal Shock Chamber
Tray Dryer
Ultra Low Temperature Freezer
Universal Water Bath
Vacuum Oven
Viscometric Bath
Water Still

Cold Chamber
Low Temp. (Horizontal / Frost Free Vertical)
Walk - In Incubator / Cooler
Walk - In Stability Chamber
Walk - In Humidity Environmental Test Chamber
Salt Spray Corrosion Cabinet
 

Designed & Hosted by : MID   Promoted by : GID